| Test performed by: |
EMACO,
INC.
7562 Trade Street
San Diego, CA 92121 |
Test Started: |
02/14/90 |
Test Completed: |
02/16/90 |
EMC Engineer: |
David Bernardin and
H.K. Mertel |
EMC Technician: |
David N. Gray |
Approved for EMACO: |
N/A |
Report Release Date: |
03/08/90 |
CERTIFICATION OF
TEST DATA |
The electromagnetic
interference test and data evaluation findings of this report have been prepared by an
independent electromagnetic compatibility consultant, EMACO, INC., in accordance with the
applicable specifications and instructions required per the attached Administrative
Summary (Section 1 of this report).
The data, data
evaluation and equipment configuration presented herein are a true and accurate
representation of the measurements of the test sample's radio frequency interference
emission and susceptibility characteristics as of the dates and at the times of the test
under the conditions herein specified. |
| Equipment Tested: |
DC Power Supply Model AB50
S/5P |
Date of Test: |
February 14, 1990 through February 16, 1991 |
|
A. H.
Mills
General Manager
EMACO, INC.
|
|
DESCRIPTION |
STATUS |
|
a) Conducted Emissions, CE01,
30 Hz to 15 kHz* |
Passed |
|
b) Conducted Emissions, CE03,
15 kHz to 50 MHz* |
Passed |
|
c) Conducted Emissions, CE07,
Time Domain Transients |
Passed |
|
d) Powerline Conducted
Susceptibility, CS01 30 Hz to 50 kHz |
Passed |
|
e) Powerline Conducted
Susceptibility, CS02 50 kHz to 400 MHz |
Passed |
|
f) Powerline Conducted
Susceptibility, CS06, Spikes |
Passed |
|
g) Radiated Emissions, RE02,
14 kHz to 1 GHz, BB; 14 kHz to 10 GHz, NB |
Failed |
|
h) Radiated Susceptibility,
RS02, Magnetic Induction Fields |
Passed |
|
i) Radiated Susceptibility,
E-Field, RS03, 10 kHz to 10 GHz |
Failed** |
|
* After the
CE01 and CE03 tests, the load box was bonded to the ground plane with conductive tape. |
|
** 5 Vdc output ripple waveform
did not change but the output DC voltage dropped below 4.9 Vdc. |
|
|
| 1.3 |
PURPOSE OF EMI and EMS TESTS |
|
|
|
The purpose of the EMI and EMS
tests were to measure levels of conducted and radiated interference emitted from the EUT
and to determine the immunity of the EUT to external electromagnetic signals and
fields. The test results were compared with the specified limits.
The EMI and EMS
measurements on this EUT were relatively complex. These tests were performed under
the direct guidance of EMACO's Principal Engineers: Mr. David Bernardin, Mr. Al
Mills and Mr. Herb Mertel. |
|
|
| 1.4 |
DESCRIPTION OF EQUIPMENT UNDER TEST |
|
|
|
The EUT was a DC
to DC power supply with the following specifications: |
| In: |
28 Vdc |
| Out: |
5 Vdc/10.0 A |
| Output
Ripple: |
100 mVp-p at 25 MHz |
|
The power supply had only one connector, a 9-pin
D-subminiature. Pin 6 was the +28 Vdc lead and Pin 1 was the 28 Vdc return.
For testing, pins 4 and 5 were soldered together to one wire to form the +5 Vdc
output. Similarly, pins 8 and 9 were connected to one wire for the 5 Vdc return.
The electrical output
load was resistor bank mounted in a metallic box. The EUT and load box were
electrically bonded to the ground plane for all tests except the conducted emissions tests
where the load box was isolated from ground but not the EUT. The output leads
between the EUT and load box were 4 inches. |
|
|
| 1.5 |
ENVIRONMENTAL CONDITIONS |
|
|
|
The environment
for the EMI tests was as follows: |
|
a) Temperature: 25° ± 5° C
b) Relative Humidity:
Laboratory Ambient
c) Altitude:
Laboratory Ambient |
|
|
| 1.6 |
POWER REQUIREMENTS |
|
|
|
The EUT was
designed to operate with 28 volts DC, 78 W power. The power used during testing was
28 Vdc, and 2.8 A. |
|
|
| 1.7 |
INTERCONNECTIONS |
|
|
|
The
interconnections during the EMI tests were as shown in Figure 1 which also shows the
general test setup used during all tests. |
|
|
| 1.8 |
APPLICABLE DOCUMENTS |
|
|
|
The following
documents were applicable to the preparation and performance of the EMI tests discussed:
|
|
MIL-STD-461C
August 4, 1986 |
Electromagnetic Emission and
Susceptibility Requirements for the Control of Electromagnetic Interference, Class A1b
Equipments (Part 2) |
|
MIL-STD-462
July 31, 1967 |
Electromagnetic Interference
Characteristics, Measurement of |
|
DI-R-7063 |
Data Item Description, EMI Test
Plan |
|
DI-R-7062 |
Data Item Description, EMI Test
Report |
|
P.O. #74636 |
Purchase Order, MARTEK POWER ABBOTT
to EMACO, INC. |
|
| Please
send site comments / suggestions to our Webmaster
Martek Power Abbott , Inc.
1111 Knox Street
Torrance, CA 90502, USA
Tel: (310) 202-8820 Fax: (310) 836-4926
© 2007 Martek Power Abbott, Inc. All Rights
Reserved.
This page last updated on
March 19, 2008 06:56 PM. |