Electromagnetic Compatibility Test Reports

 

ELECTROMAGNETIC COMPATIBILITY
TEST REPORT
ON
POWER SUPPLY
MODEL AW35S/5

TEST REPORT NO. 90438M

JANUARY 25, 1991


 

 
Test performed by: EMACO, INC.
7562 Trade Street
San Diego, CA 92121
Test Started: 02 November 1990
Test Completed: 08 January 1991
EMC Engineer: Scott Davies and
Timothy Peterson
EMC Technician: David N. Gray
Approved for EMACO: A.H. Mills
Report Release Date: 25 January 1991



CERTIFICATION OF TEST DATA

The electromagnetic interference test and data evaluation findings of this report have been prepared by an independent electromagnetic compatibility consultant, EMACO, INC., in accordance with the applicable specifications and instructions required per the attached Administrative Summary (Section 1 of this report).
The data, data evaluation and equipment configuration presented herein are a true and accurate representation of the measurements of the test sample's radio frequency interference emission and susceptibility characteristics as of the dates and at the times of the test under the conditions herein specified.

 

Equipment Tested: AC-DC Power Supply Model AW35S/5
Date of Test: November 02, 1990 through January 8, 1991
A. H. Mills
General Manager
EMACO, INC.

1.0 INTRODUCTION
1.1 ADMINISTRATIVE DATA
Customer: MARTEK POWER ABBOTT
2727 S. La Cienega Boulevard
Los Angeles, CA  90034
Contact: Mr. William Standen
(213) 202-8820
P.O. Number: 76605
Date of Test: November 2, 1990 through January 8, 1991
Equipment Under Test (EUT): AC-DC Power Supply Model AW35S/5
Input Voltage: 120Vac, 1-phase, 60Hz (nominal)
Specification: MIL-STD-461C, Part 2; MIL-STD-462
Class A1b Equipment
Disposition of Specimen: The EUT is to be picked up by MARTEK POWER ABBOTT personnel
 

 

1.2 TEST SUMMARY
The following is a summary of the EMI tests that were performed:*
DESCRIPTION STATUS
a) Conducted Emissions, CE01, 30 Hz to 15 kHz* Passed
b) Conducted Emissions, CE03, 15 kHz to 50 MHz* Passed
c) Conducted Emissions, CE07, Time Domain Transients Passed
d) Powerline Conducted Susceptibility, CS01 30 Hz to 50 kHz Passed
e) Powerline Conducted Susceptibility, CS02 50 kHz to 400 MHz Passed
f) Powerline Conducted Susceptibility, CS06, Spikes Passed
g) Radiated Emissions, RE02, 14 kHz to 1 GHz, BB; 14 kHz to 10 GHz, NB Failed
h) Radiated Susceptibility, RS02, Magnetic Induction Fields Passed
i) Radiated Susceptibility, E-Field, RS03, 10 kHz to 10 GHz Passed
* Both the MIL-STD-461C, Part 2 and Part 4 limits were plotted on the automated measurement plots per request of the customer.
1.3 PURPOSE OF EMI and EMS TESTS
The purpose of the EMI and EMS tests were to measure levels of conducted and radiated interference emitted from the EUT and to determine the immunity of the EUT to external electromagnetic signals and fields. The test results were compared with the specified limits.
The EMI and EMS measurements on this EUT were relatively complex. These tests were performed under the direct guidance of EMACO's Principal Engineers:  Mr. David Bernardin, Mr. Al Mills and Mr. Herb Mertel.
1.4 DESCRIPTION OF EQUIPMENT UNDER TEST
The EUT was an AC to DC power supply with the following specifications:
In: 120Vac, 1-phase, 60 Hz (nominal)
Out: +5 Vdc/7.0 A
Output Ripple: Less than 100 mVp-p at 25 MHz bandwidth
The power supply has a 15-pin, D-subminiature connector for the power input and output connections.  For testing, the 5 Vdc output was connected to 0.7W (35 W) resistive load.
The electrical output load was a resistor bank mounted on a metallic heatsink.  The EUT was electrically bonded to the ground plane for all tests.
1.5 ENVIRONMENTAL CONDITIONS
The environment for the EMI tests was as follows:
a) Temperature: 25° ± 5° C
b) Relative Humidity: Laboratory Ambient
c) Altitude: Laboratory Ambient
1.6 POWER REQUIREMENTS
The EUT was designed to operate with 120 Vac, 60 Hz, single-phase input power. The measured voltage and current used during testing was 119 Vac and
0.3 A (35.7 W).
1.7 INTERCONNECTIONS
The interconnections during the EMI tests were as shown in Figure 1.7-1 which also shows the general test setup used during all tests.
1.8 APPLICABLE DOCUMENTS
The following documents were applicable to the preparation and performance of the EMI tests discussed:
MIL-STD-461C
August 4, 1986
Electromagnetic Emission and Susceptibility Requirements for the Control of Electromagnetic Interference, Class A1b Equipments (Part 2)
MIL-STD-462
July 31, 1967
ElectromagneticInterference Characteristics, Measurement of
DI-R-7063 DataItem Description, EMI Test Plan
DI-R-7062 DataItem Description, EMI Test Report
P.O. #76605 PurchaseOrder, MARTEK POWER ABBOTT to EMACO, INC.


 

[Products] [Request Info.] [Terms & Conditions]
[Warranty Information] [Engineering Department]
[EMI Reports] [Environmental Reports] [Product Search]

 

Please send site comments / suggestions to our Webmaster

Martek Power Abbott, Inc.
1111 Knox Street
Torrance, CA 90502, USA

Tel: (310) 202-8820 Fax: (310) 836-4926


© 2007  Martek Power Abbott, Inc. All Rights Reserved.
This page last updated on March 19, 2008 06:57 PM.