power.jpg (5308 bytes)    


 

Environmental Test Reports

 

HIGH IMPACT SHOCK TEST REPORT
ON
ONE (1) POWER SUPPLY, PART NUMBER AB20S
ONE (1) POWER SUPPLY, PART NUMBER AB35S
AND
ONE (1) POWER SUPPLY, PART NUMBER AB50S

TEST REPORT NO. TR8027

MARCH 5, 1990


 


Written by: Debra H. Osterberg, Technical Writer Date: 12/19/89
Approved by: T.A. Nowakowski, Program Manager Date: 12/19/89
Approved by: A.S. Brockamp, Quality Assurance Manager Date: 12/19/89
1.0 PURPOSE
The purpose of this test report is to present the procedures used and the results obtained during the testing of Power Supplies, part number AB20S, s/n 333576, part number AB35S, s/n 333581, and part number AB50S, s/n 333586.  Testing was conducted in accordance with 2.1 and 2.2 below.
2.0 REFERENCES
2.1 Martek Power Abbott Electronics Purchase Order Number 74795
2.2 MIL-STD-910C
3.0 MANUFACTURER
MARTEK POWER ABBOTT ELECTRONICS
2727 S. La Cienega Boulevard
Los Angeles, CA  90034
4.0 SUMMARY
The Power Supplies, were subjected to the tests of Appendix A herein, in accordance with 2.1 and 2.2 above, as follows:

TEST MATRIX

TEST TITLE

SERIAL
NUMBERS

REPORT
PARAGRAPH

HIGH IMPACT SHOCK ---ALL--- Appendix A
The High Impact Shock test was performed by Librascope Corporation and all data obtained is presented herein in Appendix A.
This Power Supplies met the requirements of the specification without exception or deviation.
This test report represents Independent Testing Laboratories, Inc. findings and conclusions based upon the conduct of the test and procedures described herein with findings and conclusions set forth herein are expressly limited by and are subject to respect only to the particular product(s) or component(s) which were provided to Independent Testing Laboratories, Inc. by the customer for testing and evaluation purposes per written purchase orders, procedures or verbal instructions.  All findings and conclusions set forth herein are expressly limited by and are subject to the conditions, exceptions, qualifications, parameters, and limitations described and noted herein.  Independent Testing Laboratories, Inc. hereby expressly disclaims any responsibility of any nature or type whatsoever with respect to the applicability of the results set forth hereing to products or components other than the particular product(s) or component(s) which were actually physically tested by Independent Testing Laboratories, Inc. for purposes of this test report.  This report is furnished for the sole and exclusive use of the customer and may not be used by or relied upon by any other party in the absence of the express written consent of Independent Testing Laboratories, Inc.


 

[Products] [Request Info.] [Terms & Conditions]
[Warranty Information] [Engineering Department]
[EMI Reports] [Environmental Reports] [Product Search]

 

Please send site comments / suggestions to our Webmaster

Martek Power Abbott, Inc.
1111 Knox Street
Torrance, CA 90502, USA

Tel: (310) 202-8820 Fax: (310) 836-4926


© 2007 Martek Power Abbott, Inc. All Rights Reserved.
This page last updated on March 19, 2008 07:00 PM.