Product Info |
 |
35W & 50W DC/DC Converters
35W & 50W DC/DC Converters for railway applications.
The new JLM and JLHM converters for railway applications are rated at 35W and 50W respectively and offer all of the features and benefits of the standard range, including full EN50155 compliance, but in a much smaller footprint.
Both JLM and JLHM units can accept the wide range of typical railway input
voltages and outputs can be specified between 5 and 110VDC.
|
|
Features |
Wide operating temperature range |
Low component count, high reliability |
Simple construction- open frame or enclosed version |
Low cost |
Small footprint (Open frame 115x85x22 mm) |
EN50155 |
|
Input Characteristics |
Min |
Max |
Typical |
Units/Comments |
Input Voltage Range |
66 |
137.5 |
|
110 Vdc, Nominal |
|
43.2 |
90 |
|
72 Vdc, Nominal |
|
31.2 |
65 |
|
52 Vdc, Nominal |
|
21 |
50.4 |
|
36 Vdc, Nominal |
|
16.8 |
33.6 |
|
24 Vdc, Nominal |
Hold Up Time: |
|
|
10mS to EN50155 S2 (except JLH 72 Vin ver) |
|
Input Ripple: |
|
|
EN50155 |
|
Efficiency Range: |
|
|
85% Typ. |
|
|
|
|
|
|
Output Characteristics |
Min |
Max |
Typical |
Units/Comments |
Output Power(Max.): |
|
50 |
|
Watts |
Number of Outputs: |
|
1 |
|
|
|
|
|
|
|
Model |
Main Output Voltage (VDC) |
Aux 1 Nom. Vout (VDC) |
Aux 2 Nom. Vout (VDC) |
Main Output Current (Amps) |
Aux 1 Output Current (Amps) |
Aux 2 Output Current (Amps) |
JLM 1200-*/1 |
12 |
|
|
3.3 |
|
|
JLM 1500-*/1 |
15 |
|
|
2.3 |
|
|
JLM 2400-*/1 |
24 |
|
|
1.5 |
|
|
JLM 4800-*/1 |
48 |
|
|
0.72 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Isolation Characteristics |
|
|
|
|
|
|
Environmental Characteristics |
|
Operating Temperature: |
-25 to +75 deg C |
Deration: |
25 to +75 deg C no deration |
Storage Temperature: |
-40 to +80 deg C |
Cooling: |
Convection/Conduction |
Humidity: |
95% Max |
|
|
|
|
|
Mechanical Characteristics |
|
Dimensions: |
115 x 85 x 22 mm
|
Weight: |
< 500 grams
|
Case Material: |
Plated mild steel enclosure |
Mounting: |
Open frame or Chassis Mount |
Connectors: |
See Data Sheet |
|
|
|
|
|
Applicable Standards |
|
EMC |
EN50155(2007), EN50121-3-2(2006) |
Other |
EN50155(2007) |