M Series (M300S/M300T)
300 Watt Single & Triple Output Power Supply

Click
here for datasheet (pdf)
| Features |
| 300 watt single & triple output
switching power supply. |
| High efficiency, 60% minimum. |
| Meets MIL-STD-461B, MIL-STD-810C and
MIL-S-901C. |
| Specifications |
| Input: |
103.5-126.5 Vac, 47-440 Hz,
single phase. Other inputs available (H and -3 options.) |
| Efficiency: |
60% minimum at full load. |
| Line
Regulation: |
25 mV or within 0.2%,
whichever is greater, for change from low line to high line with load constant. |
| Load
Regulation: |
25 mV or 0.2%, whichever is
greater for change from no load to full load with line constant. |
| Auxiliary
Output Tracking: |
The negative output will
track the positive output within 200 mV for all rated conditions (M300T). |
| Pard (Noise and
Ripple): |
Main and Auxiliary outputs:
30 mV rms, 100 mV P-P maximum at 25 MHz bandwidth, over entire temperature range. |
| Isolation
Voltage: |
500 Vdc, input to output;
500 Vdc, input to case; 100 Vdc, output to case. |
| Insulation
Resistance: |
50 Mohms between input and
output, input and case, output and case, when measured at 50 Vdc. |
| Temperature
Range: |
Operating: 0°C to +71°C
maximum, at center of the baseplate. Storage: -55°C to +85°C, ambient. |
| Temperature
Coefficient: |
0.01% / °C for main and
auxiliary outputs over entire temp range. |
| Input Transient
Protection: |
Unit will withstand 143.8
Vac for 0.3 second, in accordance with MIL-STD-1399. |
| Load Transient
Recovery: |
Output voltage returns to
regulation limits within 1.5 milliseconds for main and 100 microseccond for auxiliary
outputs after 50% change in load current. |
| Holdup time: |
10ms after nominal input is
lost at full load. |
| Short Circuit
Protection: |
Completely protected against
a short circuit of any duration. Output automatically restores to normal when overload is
removed. |
| Current
Limiting: |
Output current is limited to
120% on main and auxiliary outputs (±10%) under overload conditions. |
| Remote Sensing: |
Regulator monitors voltage
directly at the load using extra "sensing" leads and compensates for a dc
voltage drop up to .5 volt in the load leads. |
| EMI: |
Units were designed and
tested to the requirement of MIL-STD-461B, Class A1B, for generation of and susceptibility
to radiated and conducted interference. For further details and reports, consult your
nearest sales office. |
| Reliability: |
MTBF is calculated per
MIL-HDBK-217D at 50°C baseplate temperature with maximum operating input voltage and
maximum rated output power. The MTBF for M300T at ground benign environment is 77,455
hours. |
| Environment: |
Encapsulated and
hermetically sealed to meet the environmental requirements of MIL-STD-810C and MIL-S-901C,
Class 2, including altitude (to 70,000 feet), vibration, shock, acceleration, sand, dust,
humidity, saltspray, fungus, explosion, etc. |
| Connectors: |
Standard unit is provided
with an input solder pin header and an output "hermetic seal" stud-type
connector. |

| Single Output |
 |
Output
Voltage Range |
Output
Current (Amps) |
Weight
(Lbs.) |
Size
(inches) |
| A |
B |
C |
| M300S/5-D |
4.75-5.25 |
60.0 |
7.8 |
6
x 8 x 3 |
| M300S/12-D |
11.40-12.60 |
25.0 |
7.8 |
6
x 8 x 3 |
| M300S/15-D |
14.25-15.75 |
20.0 |
7.8 |
6
x 8 x 3 |
| M300S/24-D |
22.80-25.20 |
12.5 |
7.8 |
6
x 8 x 3 |
| M300S/28-D |
26.60-29.40 |
10.7 |
7.8 |
6
x 8 x 3 |
| Triple Output |
 |
Output
Voltage (main/aux) |
Output
Current (m/aux) |
Weight
(Lbs.) |
Size
(inches) |
| A |
B |
C |
| M300T/5/12-D |
5 / ±12 |
48/2.5 |
9.2 |
6
x 8 x 3 |
| M300T/5/15-D |
5 / ±15 |
48/2.0 |
9.2 |
6
x 8 x 3 |
| Model Numbering System |
| Model Series |
Total Output
Power |
# of Outputs |
 |
Main Output
Voltage |
 |
Aux. Output
Voltage |
 |
Header Type |
 |
Options |
| M |
300 |
T |
/ |
5 |
/ |
12 |
- |
D |
- |
R |
| Options |
| A Option: |
Special Connectors. A
military-type hermetically sealed connector is provided in place of our standard input
header. To order, replace the "D" in the model with "A". |
| E Option: |
Severe Shock, Acceleration
and Vibration. Enables all units to withstand 60 g's shock, 50 g's acceleration and 30g's
vibration. To order, add "E" after "D" in the model number. |
| H Option: |
Wide Input Voltage. Units
will operate from 90 to 126.5 Vac with 20% derating in output power. To order, add an
"H" after the "D" in the model number. |
| L Option: |
Remote Turn On/Off. Provides
isolated terminals to turn output on/off with TTL logic signal. To order, add
"L" after "D" in the model number. |
| R Option: |
Remote Output Adjustment. An
adjustment potentiometer can be remotely located to adjust the output voltage. To order,
add "R" after "D" in the model number. |
| T Option: |
Wider Operating Temperature.
-20°C to +71°C. Pard (noise and ripple) specification increases to 200 mV P-P. To order,
add "T" after "D" in the model number. |
| -ER Option: |
Provides increased
reliability by using higher levels of military grade components. To order, add
"-ER" after the model number. |
| -3 Option: |
WYE Input. Changes input to
3-phase, 4-wire "WYE". To order, add "-3" to the end of the model
number. |
| -7 Option: |
50/50 Power Split. Provides
a 50/50 power split between main and auxiliary outputs (50% main output, 25% each,,
auxiliary outputs). Load regulation of auxiliary outputs will be 2 times greater than
standard model. To order, add "-7" to the end of the model number. |
|