power.jpg (5308 bytes)                            

Welcome to Martek Power Abbott



NB Series (NB100)
100 Watts, Single and Dual Outputs

 

NB100

Download NB100 spec with case drawing

Features
0.38 Inch Profile
Synchronization
Remote Turn On (TTL)
Output Voltage Trim Pin.
Single and Dual Outputs.
Over Temperature Protection.
Built-In Test (Output Power Good; Main Output).
N + 1 Redundancy (Single Output).
MIL-STD-883 Screening (Military Version).
Dual Outputs are Isolated Allowing Any Combination of Output Voltages.

 

 

How To Order
Series: NB
Total Output Power: 100
Single Output: D ("S" for Single Output)
Product Grade: M ("I" for Industrial)
Output Voltage: see below
Options: see below
 

 

 

Options
A Option: Pins out side of unit.
B Option: Pins out bottom of unit.
C Option: Pins out top of unit.
D Option: Through hole inserts (STD threaded) 0.115 01A
I Option: M2.5 inserts
Model Numbering Example:
To order a 100 watt, 15 Vout (single output), industrial grade power supply with pins out the side, the model number would be: NB100SI/15-A.  Military grade would be NB100SM/15-A.  To order a 100 watt, dual output, 15 Vdc and 15 Vdc, industrial grade power supply with pins out the top, the model number would be: NB100DI/15/15-C.  Dual output, 12 V and 15 V, military grade, would be NB100DM/12/15-C.  When ordering a dual output unit, the first output voltage in the model number is located on channel 1 (see case drawing in PDF File).
 

 

 

Accessory Products
SM1275: Input Transient Suppression Module (for 28 Vdc input only) for conformance to MIL-STD-704A & MIL-STD-1275.
NBF150: EMI Filter to meet MIL-STD-461C.


Selection Chart
Output Voltage and Output Current
Nominal Output Voltage Single Output Current
(Amps)
Dual Per Channel Current
(Amps)
2 20 10
3.3 20 10
5 20 10
5.2 19.2 9.6
12 8.3 4.2
15 6.7 3.3
24 4.2 2.1
28 3.6 1.8

 

 

Input Characteristics

Min Typ Max Units
Input Voltage 14 28 40 Vdc
Brown Out (75%) Full Load 12
Vdc
No Load Power Dissipation
2 4 Watt
Inrush Charge
2 mc
Reflected Ripple Current
15 %
Logic Disable Current (Sink)
100 150 µA
Logic Disable Power In
1.2 2.5 W
Input Ripple Rejection (120 Hz)
55
dB
Input Ripple Rejection (800 Hz)   45   dB
Efficiency (FL) 73 78-84
%
Efficiency (3.3V) (FL) 67 74
%
Efficiency (32V) (FL) 62 67   %
EMI Units conform to MIL-STD-461C (on the input leads) with companion filter
Input Transient Units conform to MIL-STD-704D (50 Vdc for 0.1 second).  Up to 100 Vdc for 100 mS with SM1275 transient suppression module.

 

 

Output Characteristics

Min Typ Max Units
Set Point Accuracy
1* % Vout
Load Regulation
5 0.2%1 mV
Line Regulation
5 0.2%1 mV
Ripple P-P (10 MHz)
(2V to 24V)

45 150 mV
Ripple P-P (10 MHz)
(28V)
  0.2 1 % Vout
Trim Range 100
110 % Vout
Remote Sense Compensation (Main Only)
0.5 Vdc
Overvoltage Protection
     (5V-28V) 125 % Vout
     (2V-3.3V) 140 % Vout
Current Sharing ±10 % Iout
Transient Response (Vout 1%) Time / Overshoot
    20 - 80% Load
350 / 300
µS/mV
    Low Line - High Line
300 / 350
µS/mV
    50 - 100% Load
250 / 300
µS/mV
Temperature Drift
0.01 0.05 %/oC
Long Term Drift   0.01 0.02 %/1KHrs
Current Limit 105 125 150 % Iout
Short Circuit Current 25   75 % Iout
Turn On Time   1.5
mS
Logic Turn On Time
1.5
mS
1 = 0.2% or 25mV whichever is greater
* = 1% or 50mV, whichever is greater
 

 

Isolation Characteristics

Min Typ Max Units
Isolation:
  Input to Output
500

Vdc
  Output to Base 250

Vdc
  Input to Base 250

Vdc
  Input to Output
  Capacitance
  0.044
µF
Insulation Resistance (@50 Vdc) 50

MOhm

 

 

Mechanical Characteristics
Weight 6.4 oz
  180 grams
Size 3.0 x 3.0 x 0.38 inch
  76.2 x 76.2 x 9.7 mm
Volume 3.42 inch3
  56 cm3


Temperature Characteristics

Min Typ Max Units
Operating -55 +100 oC
Storage (Ambient) -55
+125 oC
Over Temperature Shutdown +105 oC
Thermal Resistance Case - Ambient
12
oC/W


Environmental Screening - M Model
Stabilization Bake: +125oC for 24 hours similar to Mil-Std-883, M1108, Condition B
Temperature Cycling: 10 cycles at -55oC to +125oC (transition period 36 minutes) similar to Mil-Std-883, M1010, Condition B
Burn-in: 160 hours at +85oC minimum
Final Testing

 

Environmental Screening - I Model
Burn-in: 16 hours at +85oC minimum
Final Testing